Firstly, it is important to install the mold: pay attention to dividing the mold into sections, check if the mold is intact, and place the mold on a high-frequency machine with insulation material underneath.
Next is adjusting the mold: After the mold is installed, it must be adjusted horizontally and set parameters, and the depth on both sides should be consistent, not too deep or too shallow.Medical Antibedsore High Frequency Welders
Finally, press the high-frequency wave: align the material with the mold, step on the presser foot, and simultaneously press the power switch with both hands.

Reminder:
During the installation and debugging process of the high-frequency machine, be sure to keep both hands away from the high-frequency machine head to avoid burns. In addition, some old-fashioned hydraulic and pneumatic double head machines have an unreasonable design at the head, and hands must be taken out after adjusting the stroke to avoid injuring fingers.Home Leather Embossing High Frequency Welders
The inspection method and steps for the absence of high-frequency output faults are as follows:
Inspection method: 1) Transformer input 220V, output 6.3V; 2) Input 220V, output 7500V; 3) Check if the measuring resistor is normal; 4) Replace the pipe.
Inspection steps: 1) Damaged filament transformer; 2) High cycle transformer damage; 3) The gate resistor is burnt out; 4) The electronic tube is damaged.Heat Sealing Machine For Automotive Sun Visors